00 CAMPUS ARISTÓTELES CALAZANS SIMÕES (CAMPUS A. C. SIMÕES) CECA - CENTRO DE CIÊNCIAS AGRÁRIAS UNIDADE VIÇOSA TRABALHOS DE CONCLUSÃO DE CURSO (TCC) - GRADUAÇÃO - UNIDADE VIÇOSA Trabalhos de de Conclusão de Curso (TCC) - Bacharelado - MEDICINA VETERINÁRIA - UNIDADE VIÇOSA
Use este identificador para citar ou linkar para este item: http://www.repositorio.ufal.br/jspui/handle/123456789/13951
Tipo: Trabalho de Conclusão de Curso
Título: O uso do Termômetro infravermelho auricular em gatos eutérmicos com otites assintomáticas
Autor(es): Silva, Lívia Danielly Virginio da
Primeiro Orientador: Notomi, Marcia Kikuyo
metadata.dc.contributor.referee1: Notomi, Márcia Kikuyo
metadata.dc.contributor.referee2: Lopes, Chiara Rodrigues de Amorim
metadata.dc.contributor.referee3: Nascimento, Glaucia Grazielle
Resumo: A temperatura corpórea é um parâmetro importante no exame clínico para a identificação de alterações sistêmicas do paciente. Novos métodos de aferição da temperatura vêm sendo estudados, visando uma maior precisão. Vários estudos com cães foram realizados, porém poucos foram realizados com gatos. O presente trabalho tem como objetivo avaliar a utilização do termômetro auricular infravermelho para a aferição da temperatura corpórea em gatos domésticos e verificar a interferência da presença de otite na mensuração nesta temperatura. Para isso, foi utilizado a mensuração da temperatura auricular direita (TAD), temperatura auricular esquerda (TAE), e temperatura retal (TR) em 100 gatos. No grupo controle, os felinos que não apresentavam otite a temperatura retal máxima foi de 39,8°C enquanto as máximas da (TAD) e (TAE) foram 40,3 e 40,5°C,respectivamente; enquanto a mínima foi 36,1°C para os 3 diferentes locais. Enquanto no grupo com otite, a TR variou de 36,6 a 39,2°C, a TAD de 37,3 a 40,2°C e a TAE de 37,5a 40,1°C. Apesar das TAD e TAE diferirem significativamente da TR, as temperaturas da orelha apresentaram relação forte e positiva (p < 0,05) com a TR, com rho = 0,7 e 0,75, respectivamente. Optou-se pelos termômetros infravermelhos humano por causa da fácil disponibilidade e frequente emprego, na prática clínica. Apesar das temperaturas das orelhas direita e esquerda diferirem significativamente da temperatura retal, a temperatura das orelhas demonstrou resultados semelhantes entre si com repetitividade, podendo ser utilizada na avaliação clínica de gatos, desde que sejam determinados valores de referência.
Abstract: Body temperature is an important parameter in the clinical examination to identify systemic changes in the patient. New methods of measuring temperature have been studied, aiming at greater accuracy. Several studies have been carried out with dogs, but few have been carried out with cats. This study aims to evaluate the use of an infrared ear thermometer to measure body temperature in domestic cats and to verify the interferenceof the presence of otitis in measuring this temperature. For this, we used the measurement of right ear temperature (RAT), left ear temperature (SAT), and rectal temperature (TR) in 100 cats. In the control group, the felines that did not present otitis the maximum rectal temperature was 39.8°C while the maximums of (TAD) and (TAE) were 40.3 and 40.5°C, respectively; while the minimum was 36.1°C for the 3 different locations. While in the group with otitis, TR ranged from 36.6 to 39.2°C, TAD from 37.3 to 40.2°C and TAE from 37.5 to 40.1°C. Although TAD and TAE differ significantly from TR, ear temperatures showed a strong and positive relationship (p < 0.05) with TR, with rho = 0.7 and 0.75, respectively. Human infrared thermometers were chosen because of their easy availability and frequent use in clinical practice. Despite the temperature of the right and left ears differing significantly from the rectal temperature, the temperature of the ears showed similar results with repeatability, and can be used in the clinical evaluation of cats, as long as reference values are determined.
Palavras-chave: Temperatura
Temperature
Termômetro auricular
Auricular thermometer
Gatos domésticos
Domestic cats
Infravermelho
Infra-red
Avaliação clínica
Clinical evaluation
CNPq: CNPQ::CIENCIAS AGRARIAS::MEDICINA VETERINARIA::CLINICA E CIRURGIA ANIMAL::CLINICA VETERINARIA
Idioma: por
País: Brasil
Editor: Universidade Federal de Alagoas
Sigla da Instituição: UFAL
metadata.dc.publisher.department: Curso de Medicina Veterinária - Bacharelado
Citação: SILVA, Lívia Danielly Virginio da. O uso do Termômetro infravermelho auricular em gatos eutérmicos com otites assintomáticas. 2022. 21 f. Trabalho de Conclusão de Curso (Bacharelado em Medicina Veterinária) – Campus de Engenharias e Ciências Agrárias, Polo Viçosa, Universidade Federal de Alagoas, Viçosa, 2022.
Tipo de Acesso: Acesso Aberto
URI: http://www.repositorio.ufal.br/jspui/handle/123456789/13951
Data do documento: 12-dez-2022
Aparece nas coleções:Trabalhos de de Conclusão de Curso (TCC) - Bacharelado - MEDICINA VETERINÁRIA - UNIDADE VIÇOSA

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
O uso do Termômetro infravermelho auricular em gatos eutérmicos com otites assintomáticas.pdfO uso do Termômetro infravermelho auricular em gatos eutérmicos com otites assintomáticas502.33 kBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.